NIBCO INC -- PVC SOLVENT CEMENT -- 8040-00N059285
===================== Product Identification =====================
Product ID:PVC SOLVENT CEMENT
MSDS Date:04/01/1990
FSC:8040
NIIN:00N059285
=== Responsible Party ===
Company Name:NIBCO INC
Address:2929 WEST MAGAZINE ST
City:LOUISVILLE
State:KY
ZIP:40211-1351
Country:US
Info Phone Num:303-823-5718
Emergency Phone Num:303-823-5718
CAGE:61623
=== Contractor Identification ===
Company Name:CELANESE PIPING SYSTEMS
CAGE:14007
Company Name:NIBCO INC
Address:2929 WEST MAGAZINE ST
Box:City:LOUISVILLE
State:KY
ZIP:40211
Country:US
Phone:303-623-5716
CAGE:61623
============= Composition/Information on Ingredients =============
Ingred Name:FURAN, TETRAHYDRO-; (TETRAHYDROFURAN) (CERCLA) FL PT: 5F,
-15C
CAS:109-99-9
RTECS #:LU5950000
Fraction by Wt: 50-80%
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/250STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 10-15%
OSHA PEL:1000 PPM
ACGIH TLV:750PPM/1000STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:PVC RESIN
Fraction by Wt: 10-14%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:CYCLOHEXANONE (CERCLA)
CAS:108-94-1
RTECS #:GW1050000
Fraction by Wt: 5-14%
OSHA PEL:50 PPM, S
ACGIH TLV:25 PPM, S
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:FUMED SILICA
CAS:68583-49-3
Fraction by Wt: 2-3%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:2-BUTANONE (MEK) (SARA 313) (CERCLA)
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: <1%
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/300STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:CARBON BLACK
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: <1%
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:5F,-15C
Lower Limits:1.8%
Upper Limits:11.8%
Extinguishing Media:FOR SML FIRES USE DRY CHEM, CO*2, WATER/FOAM
EXTINGUISHER. FOR LGE FIRES EVACUATE AREA & CALL FIRE DEPARTMENT
IMMED.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:FIRE HAZARD BECAUSE OF LOW FLASH POINT
AND HIGH VOLATILITY. VAPORS ARE HEAVIER THAN AIR AND MAY TRAVEL TO
SOURCE OF IGNITION.
============= Exposure Controls/Personal Protection =============
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:151F,66C
Vapor Pres:145 @ 20C
Vapor Density:2.5
Spec Gravity:0.94
Evaporation Rate & Reference:5.5-6 (BUTYL ACETATE=1)
Solubility in Water:SOLVENTS (SUP DAT)
Appearance and Odor:GRAY LIQUID WITH ETHER-LIKE ODOR
Percent Volatiles by Volume:85
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
CAUSTICS, AMMONIA, INORGANIC ACIDS, CHLORINATED COMPOUNDS, STRONG
OXIDIZERS AND ISOCYANATES.
Stability Condition to Avoid:KEEP AWAY FROM HEAT, SPARKS, OPEN FLAME &
OTHER SOURCES OF IGNIT. ALL HNDLG EQUIP SHOULD BE ELECTRICALLY
GROUNDED.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.